Winter hazard facts: sources

Sources for the rotating winter hazard facts on the homepage. Checked October 9, 2026.

Cold-day counters

Days this season at Fairbanks International Airport (station PAFA, GHCN USW00026411), counted by the official daily low temperature: at or below 32°F, below 0°F, and below −20°F. Season: July 1 to June 30. Last season is the previous complete July 1 to June 30 season, counted the same way. Source for both: NOAA Regional Climate Centers ACIS daily minimum temperature.

This season data ↗ · Last season data ↗

Winter hazard facts

  1. Fairbanks hit -66°F on January 14, 1934, its coldest on record.

    NWS Fairbanks, “Fairbanks Climate Reference: January” (period of record 1904 to present): https://www.weather.gov/media/afg/climate/Fairbanks_Records_January.pdf
    NOAA Monthly Weather Review, 1934: https://library.oarcloud.noaa.gov/docs.lib/htdocs/rescue/mwr/062/mwr-062-08-0269.pdf

    Record lows table, January 14: record low -66, year 1934.

  2. In January 1934, Fairbanks averaged -51°F for three straight weeks.

    NOAA Monthly Weather Review, Vol. 62 (1934): https://library.oarcloud.noaa.gov/docs.lib/htdocs/rescue/mwr/062/mwr-062-08-0269.pdf

    “The most severe cold period on record at Fairbanks was that of January 1934, when the temperature averaged -51.0° for 3 weeks.”

  3. In University of Illinois tests, an exposed water pipe in 0°F air froze solid in about 4¾ hours.

    Gordon, J.R., “An Investigation into Freezing and Bursting Water Pipes in Residential Construction,” Research Report 96-1, Building Research Council, University of Illinois (1996): https://www.ideals.illinois.edu/items/54859

    “At the coldest temperature of 0°F (-17.78°C), time to blockage is seen to be around 4-3/4 hours.” 0°F was the coldest temperature tested.

  4. IBHS says burst pipes drive the most extreme-cold damage, especially when power is out over 24 hours.

    IBHS, “State of the Risk: Interior Water Damage” (December 2024): https://ibhs1.wpenginepowered.com/wp-content/uploads/Interior-Water-White-Paper.pdf

    “The leading culprit driving damage from extreme cold was identified as burst plumbing pipes which have been a common occurrence in sub-freezing weather, especially in situations where power has failed for periods longer than twenty-four hours.”

  5. At -40°F, Dow's tables list about 37% propylene glycol to prevent burst pipes. Pros typically cap loops at 40%.

    Dow, “Engineering and Operating Guide for DOWFROST and DOWFROST HD,” Table 4: https://www.dow.com/documents/180/180-01286-01-engineering-and-operating-guide-for-dowfrost-and-dowfrost-hd.pdf (about 37%)
    Typical 40% loop cap: Full Tilt MC field practice

    Table 4, row -40°F: burst protection 36.6% (DOWFROST) / 37.2% (DOWFROST HD) propylene glycol.

  6. Snow or ice over boiler exhaust and intake vents can cause a carbon monoxide hazard, so keep them clear.

    Natural Resources Canada, “Natural Gas-Fired Hot Water Boiler: Retrofit Installation Guidelines”: https://natural-resources.canada.ca/sites/nrcan/files/oee/buildings/pdf/NRCan_Boilers_en.pdf
    NFPA, “Carbon Monoxide Safety”: https://www.nfpa.org/education-and-research/home-fire-safety/carbon-monoxide

    “During snowy or cold weather, both exhaust and intake points must be clear of snow and ice.” (NRCan). “During and after a snowstorm, make sure vents for the dryer, furnace, stove, and fireplace are clear of snow build-up.” (NFPA)

  7. Frozen condensate drains can shut down high-efficiency heating equipment, so insulate any drain line that could freeze.

    U.S. DOE Standard Work Specifications, 5.0102.1 “Condensate Removal”: https://sws.nlr.gov/spec/501021

    “When there is potential for condensation or freezing of the drain line, insulate condensate drain lines to a minimum of R-4.” The same specification calls for stopping system operation if condensate is not draining.

  8. ASHRAE's heating design temperature for Fairbanks is -40°F, the cold day systems should be sized to handle.

    RESNET, Appendix A, “Design Temperature Limits by State and County” (ASHRAE 2013 Handbook of Fundamentals, 99% heating design temperatures): https://www.resnet.us/wp-content/uploads/Appendix-A-HVAC-Design-Temperature-Limits-v1-2018-02-07_webpubcmnt.pdf
    Alaska Housing Finance Corporation building manual, Chapter 8: https://www.ahfc.us/iceimages/manuals/building_manual_ch_08.pdf

    Fairbanks North Star: 99.0% heating design temperature -40, source ASHRAE.

  9. A one-eighth inch pipe crack can leak more than 250 gallons of water a day (IBHS).

    IBHS, via Insurance Journal (November 22, 2005): https://www.insurancejournal.com/news/national/2005/11/22/62297.htm

    “a one-eighth inch (3-millimeter) crack in a pipe can spew out more than 250 gallons of water a day.”

  10. Going away in winter? The Red Cross says to keep the heat no lower than 55°F.

    American Red Cross, “Frozen Pipes”: https://www.redcross.org/get-help/how-to-prepare-for-emergencies/types-of-emergencies/winter-storm/frozen-pipes.html

    “If you will be going away during cold weather, leave the heat on in your home, set to a temperature no lower than 55° F.”